• Low Temp Thermostatic Bath
  • DC-0515N
  • Low Temp Thermostatic Bath
  • Temperature range: -5~100℃, capacity: 15L, with internal and external circulation
DC-0515N Low Temp Thermostatic Bath adopts the new international advanced refrigeration system with stable and reliable performance. It has both internal and external circulation functions: the internal circulation can directly conduct constant temperature testing on test samples or products being produced within the tank, while the external circulation function uses a high-pressure pump to circulate and maintain the temperature of the liquid medium inside the tank, increasing the uniformity of the temperature inside the tank and reducing temperature fluctuations.

a

Product Introduction
DC-0515N Low Temp Thermostatic Bath adopts a new international advanced refrigeration system with stable and reliable performance. It has both internal and external circulation functions: the internal circulation can directly conduct constant temperature testing on test samples or products being produced within the tank, while the external circulation function uses a high-pressure pump to circulate and maintain the temperature of the liquid medium inside the tank, increasing the uniformity of the temperature inside the tank and reducing temperature fluctuations. The principle is to use the outlet to bring the constant temperature medium in the tank outside through an insulated hose, establishing an external constant temperature environment, and providing a constant temperature cooling liquid for testing or production, with a uniform and constant liquid temperature environment. The constant temperature cooling liquid can be circulated and reused. This instrument is widely used in research departments such as petroleum, chemical, electronic instruments, physics, chemistry, bioengineering, medical and health, life sciences, light industry, food, physical property testing, and chemical analysis, as well as in higher education institutions, enterprise quality inspection and production departments. It can also provide users with a controlled hot and cold, uniform and constant liquid temperature environment during work, and can be used for constant temperature testing or testing of test samples or products, as well as a power source or refrigeration source for direct or auxiliary heating or refrigeration.


Product Features
1. Unique large-screen backlit LCD display, clear and concise display of set temperature, actual temperature, and independent start/stop of "heating", "cooling", "internal/external circulation" and other functions, as well as work status information;
2. The control part adopts ABS modular design, with a streamlined appearance and exquisite workmanship of the cabinet front panel and table. The unique humanized R-rounded corner design structure can prevent the operator from being injured by the sharp corners of the cabinet inadvertently. The whole set is packaged with molded foam to avoid damage during transportation;
3. High-performance stirring and circulating motor with low noise, low heat generation, fully enclosed and long service life. The use of a heat-free circulating pump avoids the effect of traditional water pumps on the temperature field of the tank due to their own heat generation.
4. The countertop and inner tank are made of 304 stainless steel, and the refrigeration coil is equipped with positioning and surface treatment processes to effectively solve the problems of shaking, corrosion, rust and other phenomena during transportation or use;
5. The motor impeller is fully enclosed to prevent safety hazards. Multiple safety protections: heating tube low liquid level dry burning protection, alarm with both light and sound;
6. It has power-off protection and over-temperature alarm function, providing multiple security measures;
7. Fully enclosed compressor refrigeration, the refrigeration system has multiple protection devices such as overheating and overcurrent;
8. The instrument is specially designed with flexible removable door panels around it. For better refrigeration effect and convenient and simple dust cleaning after long-term operation, no disassembly tools are needed;
9. The instrument has stable and reliable operation, convenient and safe operation, and the instrument has temperature calibration and self-tuning functions;
10. The circulation interface and drainage outlet are all made of 304 stainless steel tower joints, with quick and reliable installation. The drain valve is designed as a hidden built-in style, which is beautiful and can effectively avoid unnecessary damage during delivery or transportation;
11. The instrument comes with two-section circulating silicone hoses and insulation sleeves for flexible use by customers;


Safety Protection Devices
1. Equipped with power-off protection function
2. Equipped with upper and lower temperature alarm setting function
3. Low water level protection and alarm function
4. Temperature out-of-control protection and alarm function
5. Heating tube equipped with low water level anti-dry burning and explosion-proof function.


Optional Function Guide
1. Optional external PT100 temperature sensor, which can detect and control the temperature of the external system in real time during external circulation.
2. Optional built-in 1-30 segment temperature control program, which can perform automatic program temperature control and display the set temperature-time program running status in real time.
3. Optional RS232 or RS485 communication interface, easy to connect with upper computer using ModbusRTU communication protocol.
4. Optional design and installation of magnetic stirring system, which can directly stir the samples in the beaker in the constant temperature bath without the need for an external vertical stirrer, reducing cumbersome operations and achieving closed processing, while reducing the fog loss generated during the stirring process.
5. Optional cooling coil built-in in the tank body, which can quickly cool and control the heat release reaction of the system.
6. Optional height-adjustable immersion load platform, which can easily adjust the liquid level height of the immersed sample.


Technical Parameters                
Model Temperature Range
(℃)
Digital Resolution
(℃)
Internal Tank Volume
Length*Width*Height (mm)
Circulation Pump Flow Rate
(L/min)
Working Tank Opening
(mm)
Total Volume
(L)
Net Weight
(kg)
Overall Dimensions
Depth*Width*Height (mm)
DC-0515N -5~100 0.1/0.01 300·250·210 10 235·160 15 35 520·380·830
DC-1015N -10~100 0.1/0.01 300·250·210 10 235·160 15 35 520·380·830
DC-2015N -20~100 0.1/0.01 300·250·210 10 235·160 15 35 520·380·830
DC-3015N -30~100 0.1/0.01 300·250·210 10 235·160 15 40 500·400·1000
DC-4015N -40~100 0.1/0.01 300·250·210 10 235·160 15 40 500·400·1000


Manufacturer's Friendly Reminder - Considerations for Choosing a Constant Temperature Bath:
1. First consider the range of temperatures needed for use. What medium will be used as the temperature field carrier? Different temperature ranges require different media. Common choices include: ethylene glycol for water (low temperature), alcohol (ultra-low temperature), pure water (5-95°C), imported dimethyl silicone oil (applicable to high and low temperatures), etc.
2. Choose a constant temperature bath with a capacity that meets your actual needs. The correct calculation method for effective working volume is: the size of the working bath opening plus the depth of the bath, in millimeters.
3. Consider the required temperature uniformity of the constant temperature bath. Our company offers two types: standard type: ±0.1°C; and high-precision type: ±0.01°C.
4. Determine whether an external circulation function is required and what is the maximum flow rate needed.


Single Page - Color Page    
Name: Author: Action:
Low Temp Thermostatic Bath DC-0515N dry bath Download


Related products  
Name: Model:
Low Temp Water Bath DC-0520N
Low Temp Thermostatic Bath DC-0515N
cooling thermostatic bath DC-0510N
Product List
DC-0515N Unit
Host Machine Unit
Thermostatic bath cover piece
Thermostatic bath hose piece
Power cord piece
User manual copy
Warranty card copy
Certificate of qualification copy
Description
1
1
2
1
1
1
1